Q-2, r. 4.1 - Clean Air Regulation

Full text
SCHEDULE E
(s. 51)
FORMULAS FOR CALCULATING ESTIMATIONS OF VOLATILE ORGANIC COMPOUND EMISSIONS
Table I


Category of operation Category of equipment parts Formula


PETROLEUM REFINERY Overpressure valves E=1.36 x 10-5 x C0.589
_______________________________________________________

PETROCHEMICAL PLANT Gate valves and other valves E=2.29 x 10-6 x C0.746
_______________________________________________________

OIL TERMINAL Pump, compressor and agitator E=5.03 x 10-5 x C0.610
seals
_______________________________________________________

Joints and connections E=4.61 x 10-6 x C0.703
_______________________________________________________

Open pipes E=2.20 x 10-6 x C0.704


ORGANIC CHEMICAL PLANT Gate valves and other E=1.87 x 10-6 x C0.873
valves (gas)
_______________________________________________________

Gate valves and other E=6.41 x 10-6 x C0.797
valves (liquid)
_______________________________________________________

Pump, compressor, agitator and E=1.9 x 10-5 x C0.824
overpressure valve seals and
other valve seals (liquid)
_______________________________________________________

Joints and connections E=3.05 x 10-6 x C0.885
_______________________________________________________

Open pipes E=6.41 x 10-6 x C0.797


Table II


Category of operation Category of equipment parts Formula


PETROLEUM REFINERY Overpressure valves E=4 x 10-6 kg/h/part
_______________________________________________________

PETROCHEMICAL PLANT Gate valves and other valves E=7.8 x 10-6 kg/h/part
_______________________________________________________

OIL TERMINAL Pump, compressor and agitator E=2.4 x 10-5 kg/h/part
seals
_______________________________________________________

Joints and connections E=3.1 x 10-7 kg/h/part
_______________________________________________________

Open pipes E=2.0 x 10-6 kg/h/part


ORGANIC CHEMICAL PLANT Gate valves and other E=6.6 x 10-7 kg/h/part
valves (gas)
_______________________________________________________

Gate valves and other E=4.9 x 10-7 kg/h/part
valves (liquid)
_______________________________________________________

Pump, compressor, agitator, E=7.5 x 10-6 kg/h/part
overpressure valve and other
valve seals (liquid)
_______________________________________________________

Joints and connections E=6.1 x 10-7 kg/h/part
_______________________________________________________

Open pipes E=2.0 x 10-6 kg/h/part


For the purposes of the above tables,
“E” is the total or specific organic compound emissions in kg/h per part; and
“C” is the measured concentration of total or specific organic compounds expressed in ppmv; if the concentration “C” measured for a part is greater than 10,000 ppmv (C > 10,000 ppmv), use C = 33,620 ppmv in the emission calculation equation for that part.
O.C. 501-2011, Sch. E.